Smoke control dampers

Automatic or manual dampers for smoke control in SEFFC systems.


SR-Gravity-Circular-F400 - Gravity damper for axial detectors

Description

Non-return damper for circular ESTR-CA extractors, certified with the F400 extractor.
Prevents air from entering when the fan is not operational in the protected environment.

  • Horizontal Flow
  • Always positioned on the smoke exhaust side

Reference Standards

SR dampers are CE marked according to UNI EN 12101-3 regulations.


Classification

F300/F200-120 (300/200 °C-120 min)
F400-120 (400 °C-120 min)
EN 12101-3


SR-GRAVITY-RECTANGULAR-F400 - Gravity damper for axial fan

Description

Non-return damper for rectangular ESTR-CA extractors, certified with the F400 extractor.
Prevents air from entering when the fan is not operational in the protected environment.

  •   Horizontal Flow
  •   Always positioned on the smoke exhaust side

Reference Standards

SR dampers are CE marked according to UNI EN 12101-3 regulations.


Classification

F300/F200-120 (300/200 °C-120 min)
F400-120 (400 °C-120 min)
EN 12101-3


SSAM - Louver damper for single compartment ducts

Description

Rectangular smoke control damper for smoke and heat exhaust systems in single compartments


Reference Standards

SSAM dampers are CE marked according to UNI EN 12101-8 regulations under EU Regulation 305/2011 and tested according to EN 1366-10.


Classification

EN 13501-4
E600 120 (ve - i< -> o) S 1500 Cmod MA Single


SMAM - Louver damper for multiple compartment ducts

Description

Rectangular smoke control damper for smoke and heat exhaust systems in multiple compartments


Reference Standards

SMAM dampers are CE marked according to UNI EN 12101-8 regulations under EU Regulation 305/2011 and tested according to EN 1366-10.


Classification

EN 13501-4
EI 120 (i-o) S1000 Cmod HOT 400/30 MA Multi


SSP - Louvre damper for single compartment ducts

Description

Rectangular smoke control damper for smoke and heat exhaust systems in a single compartment


Reference Standards

SSP dampers are CE marked according to UNI EN 12101-8 regulations under EU Regulation 305/2011 and tested according to EN 1366-10.


Classification

EN 13501-4
E600 120 (Ved - i <-> o) S 1500 Cmod AA Single


SMPMA - Louvre damper for multiple compartment ducts with MA actuator

Description

Rectangular smoke control damper for smoke and heat exhaust systems in multiple compartments


Reference Standards

SMPMA dampers are CE marked according to UNI EN 12101-8 regulations under EU Regulation 305/2011 and tested according to EN 1366-10.


Classification

EN 13501-4
EI 120 (i<->o) S1000 Cmod HOT 400/30 MA Multi


SMP - Louvre damper for multiple compartment ducts

Description

Rectangular smoke control damper for multi-compartment smoke and heat exhaust systems


Reference Standards

SMP dampers are CE marked according to UNI EN 12101-8 regulations under EU Regulation 305/2011 and tested according to EN 1366-10.


Classification

EN 13501-4
EI 120 (i<->o) S 1500 C10000 AA Multi